ValuSignal

UAD 3.6 series Part 3 of 7

The Signal / UAD 3.6 / November 8, 2026

Measuring the houseANSI Z765, level breakdowns and the required sketch

For decades a Uniform Residential Appraisal Report reduced a house to one Gross Living Area figure and a basement percentage. UAD 3.6 reports square footage as six discrete fields per unit, a per level room table and a sketch tied to a named measurement standard. A rules engine can audit each field, and a reviewer can trace every square foot to a level and a category.

AI-generated illustration of a fictional houseResearch checked November 2, 20269 chapters

Key points

  1. The Area Breakdown fields (10.003 to 10.008) are always populated, one set per unit, and they replace both the Gross Living Area number and the free text basement line.
  2. The over 50 percent, under 7 foot rule reclassifies an entire level when more than half its area fails the ceiling height test, but only the failing portion when the test is applied at the room scale instead.
  3. Levels in Unit (10.017) reflects the number of rows in the Level and Room Detail table. Fannie Mae and Freddie Mac's Lessons Learned job aid lists row count mismatches as an error pattern it has observed.
  4. In Appendix F-1's worked example, reclassifying identical below grade space from unfinished to finished swings an otherwise identical $425,000 sale's price per square foot from $118 to $79.

Collateral risk teams can check Gross Living Area the way they check the rest of a loan file, field by field, instead of trusting one hand typed total.

This is Part 3 of our seven part series on the redesigned appraisal report. Part 1 covered how the report decides its shape. This part uses SF3, a sample scenario the GSEs published that includes a primary dwelling and an accessory dwelling unit, as the running example. It reproduces seven of the GSEs' nine worked examples for the section's least intuitive rule.

01 / One number becomes sixFrom one GLA line to a field group

From one Gross Living Area line to six Area Breakdown fields

The legacy Form 1004 reported a single "Square Feet of Gross Living Area Above Grade" line, plus a free text "Basement and Finished Rooms Below Grade" row in the sales grid.4 Gross Living Area and "basement" are retired Selling Guide terms.8 UAD 3.6 replaces both with six Area Breakdown fields per unit, 10.003 to 10.008, and requires all six. Two of them, 10.004 and 10.007, report nonstandard area and display only when their value is nonzero.1

Legacy Form 1004: Finished area above grade contains rooms, bedrooms, baths and one Square Feet of Gross Living Area Above Grade line.Legacy Form 1004 sales comparison grid: Above Grade Room Count, Gross Living Area in square feet, and a free text Basement and Finished Rooms Below Grade row.
UAD 3.6 Area Breakdown, the six always required fields
FieldLabelFormat
10.003Finished Above GradeSq. ft.
10.004Finished Above Grade (Nonstandard)Sq. ft.; does not display if 0
10.005Unfinished Above GradeSq. ft.
10.006Finished Below GradeSq. ft.
10.007Finished Below Grade (Nonstandard)Sq. ft.; does not display if 0
10.008Unfinished Below GradeSq. ft.
Form 1004/70, March 2005, pp. 1 to 2.4 Redrawn from Appendix F-1 v1.4, p. 127.1

SF3 shows the six numbers in practice: Finished Above Grade 3,304 sq ft, Unfinished Above Grade 0 sq ft, Finished Below Grade 1,344 sq ft, Unfinished Below Grade 616 sq ft, totaling 5,264 sq ft across every field.3

The blank, rendered Unit Interior section of the URAR as it appears on a report today: the Area Breakdown grid, Levels in Unit and the Level and Room Detail table, empty and ready for an appraiser to populate.
What the rendered Unit Interior section looks like today, blank. Appendix C-1, p. 14.2
A tape measure extended along the exterior foundation wall of a two story suburban house, a mature oak in the background.
ANSI Z765-2021 measures the exterior wall, not the floor plan a room suggests.AI-generated illustration
02 / The measurement standard7.000, 7.001 and the gap at 7.003

How UAD 3.6 reports the measurement standard

ANSI. American National Standards Institute. ANSI Z765-2021 is the measurement standard UAD 3.6 requires for attached and detached single-family dwellings, including manufactured homes. Z765-2021 is required for attached and detached single family dwellings, including manufactured homes.7 Condo and co-op apartment units use interior perimeter measurement instead. Measurement Standard (7.001) offers three allowable answers: ANSI, AMS. "American Measurement Standard," one of three allowed answers for Measurement Standard (7.001) in Appendix F-1. F-1 gives no further definition for it., or Other with a required description.

F-1 lists AMS. "American Measurement Standard," one of three allowed answers for Measurement Standard (7.001) in Appendix F-1. F-1 gives no further definition for it., American Measurement Standard, as one of those three answers, but gives no definition for it anywhere else in the document.

Sketch Commentary. Field 7.003: free-form text that reports any required ANSI Declaration, an explanation for an alternate measurement standard, or the reason no sketch was provided. It has no discrete enumeration for these. are reported in free form Sketch Commentary (7.003). That field has no dedicated enumeration for the declaration type, so this one part of an otherwise structured section stays free text.1

An upper level room beneath a sloped roofline, taller at one side than the other, a desk positioned in the taller portion.
AI-generated illustration.

Fannie Mae adopted ANSI in April 202212; Freddie Mac followed in November 2023.13 SEL-2025-04 retired the GLA, basement and GXX001 terminology for loan applications dated on or after September 8, 2025.8 The UAD 3.6 mandate date was November 2, 2026; approved sellers may still submit UAD 2.6 through May 19, 2027. The full timeline lives in our exception and delay feature; this section covers the short version.

Sketch fields, 7.000 to 7.003
FieldLabelWhen to includeFormat
7.000Sketch or Floor Plan ProvidedAlways requiredYes | No
7.001Measurement StandardRequired if 7.000 = YesANSI | AMS (American Measurement Standard) | Other (Describe)
7.003Sketch CommentaryIf applicableFree-form: ANSI Declaration(s), alternate-standard explanation, or reason no sketch was provided

Source: Appendix F-1 v1.4, p. 92.1

A rules engine can confirm that 7.000 and 7.001 are populated. Telling which of the three ANSI declaration types applies still takes reading 7.003 as free text. Budget a manual or NLP review step for that one field.

03 / The 50 percent ruleLevel scale versus room scale

How the over 50 percent, under 7 foot rule works

The ceiling height test sets 7 ft. as the standard minimum. The job aid's examples treat the gray zone, less than 7 ft. but greater than 5 ft., as nonstandard finished area. If more than 50 percent of a level, or of a room scale area within an otherwise compliant level, falls under 7 ft., the entire area, including the compliant portion, is reported Finished (Nonstandard).5

Three phases of one rule

  1. The ceiling height test

    7 ft. is standard. The job aid's examples count less than 7 ft. but greater than 5 ft. as nonstandard finished area.

  2. The over 50 percent threshold

    More than half a unit's area under 7 ft. moves the entire unit into the nonstandard bucket.

  3. Level scale versus room scale

    Example 7: an entire 1,000 sq ft level, 60 percent under 7 ft., reclassifies as nonstandard. Example 9: one 280 sq ft sloped-ceiling room reclassifies on its own, and the dwelling's other 2,100 sq ft of standard finished area stays unchanged.

Slope ceiling classifier

Set an area and its under 7 ft. portion to check which Area Breakdown field applies

Load one of the GSEs' worked examples first, then try your own numbers.

Scale
Grade
All seven GSE worked examples, as a table
GSE ANSI Reporting Requirements job aid, Examples 1, 4 to 9
ExampleScenarioScaleStandardNonstandard
1One level, ceilings 7 ft or more throughoutlevel1,291 sq ft0 sq ft
4Two level: 1,500 sq ft above grade, plus a 1,500 sq ft unfinished basement, ceilings 7 ft or morelevel1,500 sq ft0 sq ft
5Two level: 1,500 sq ft basement, 1,200 finished and 300 unfinished, ceilings 7 ft or morelevel1,200 sq ft0 sq ft
6Two level: 1,500 sq ft basement, 900 sq ft finished standard plus 600 sq ft finished under 7 ftlevel900 sq ft600 sq ft
7Two level: second level 1,000 sq ft, 600 sq ft (60%) under 7 ftlevel0 sq ft1,000 sq ft
8Three level: a third-level 1,000 sq ft with 600 sq ft (60%) under 7 ft, above a compliant second level and a finished basementlevel0 sq ft1,000 sq ft
9Two level dwelling with a sloped-ceiling office, more than half the room under 7 ft; the job aid reports the dwelling’s Finished Above Grade as 2,100 sq ft standard plus this 280 sq ft room, as one dwelling wide total across both levelsroom0 sq ft280 sq ft

Source: GSE ANSI Reporting Requirements job aid, Examples 1 to 9.5 Examples 2 and 3 test ADU access type instead of this rule, so they are left out of the tool.

Examples 7 and 9 reach different results on purpose. In Example 7, a 1,000 sq ft second level with 600 sq ft (60 percent) under 7 ft. fails the test as one unit, so the entire level becomes Finished Above Grade (Nonstandard). In Example 9, a 280 sq ft sloped ceiling office fails the test because the job aid applies it to the room, and only that room becomes nonstandard. The job aid reports the dwelling's other 2,100 sq ft as standard Finished Above Grade, a single total across both levels.

04 / A table for every level10.017 and the Level and Room Detail rows

Levels in Unit comes from the room table's row count

Levels in Unit (10.017) reflects the number of rows in the Level and Room Detail table.1 A sunken living room or a split foyer landing does not count as a level. An uppermost story counts as a level only with permanent stair access; it is an attic otherwise. Levels are specific to each unit: an ADU reports its below grade space in its own Unit Interior section, separate from the main unit's.

Fannie Mae and Freddie Mac's Lessons Learned job aid lists Levels in Unit versus row count mismatches as an error pattern it has observed, even though the field is specified to reflect the row count.6 Appendix H-1's compliance rules (v1.5) check that each level field is present. They do not check that 10.017 matches the row count.11

SF3's Unit Interior, field by field

The printed report

SF3 Unit Interior, Primary Dwelling: Area Breakdown with Finished Above Grade 3,304, Unfinished Above Grade 0, Finished Below Grade 1,344, Unfinished Below Grade 616, Levels in Unit 3, and a Level and Room Detail table for Level B1, Level 1 and Level 2.
GSE Sample Appraisal SF3, v1.4, PDF p. 7 of 23.3

The same answers as data fields

  1. 10.017Levels in Unit3
  2. 10.029Level B1Below Grade, Walk Out
  3. 10.031/10.032Level B1, finished and unfinished1,344 sq ft finished, 616 sq ft unfinished
  4. 10.029Level 1Above Grade
  5. 10.031Level 1, finished1,960 sq ft
  6. 10.029Level 2Above Grade
  7. 10.031Level 2, finished1,344 sq ft
The level table
LevelGradeFinishedUnfinished
Level B1Below Grade, Interior and Exterior Access, Walk Out1,344 sq ft616 sq ft
Level 1Above Grade1,960 sq ft0
Level 2Above Grade1,344 sq ft0
Total finished, all levels4,648 sq ft

Recompute Levels in Unit from the row count at intake. The GSEs have already flagged this data as error prone, and a simple count is enough to check it.

Levels and Level and Room Detail fields
FieldLabelNotes
10.017Levels in UnitNumber; reflects the row count of the Level and Room Detail table (10.029 to 10.033), a computed value
10.029Level in UnitLevel 1, Level 2... / Level B1, Level B2...; must start with B if partially or fully below grade
10.030Grade Level DetailAbove Grade | Fully Below Grade | Partially Below Grade, plus Below Grade Access and Exterior Access type
10.031/10.032Finished / Unfinished AreaSq. ft.; finished combines standard and nonstandard, the only place they are combined
10.033Room SummaryCount by room type: Bedroom, Bath-Full, Bath-Half, Kitchen, Family Room and 14 more

Source: Appendix F-1 v1.4, pp. 130 to 134.1

05 / The sample house, broken downHow SF3's sketch adds up

Three levels and a cottage: how SF3's sketch adds up

SF3 has a primary dwelling with three levels, B1 below grade walk out, Level 1 and Level 2, plus a separate accessory dwelling unit the sample calls the Cottage. SF3’s name for its accessory dwelling unit: a 464 sq ft, one-level structure with exterior access only..3 The sketch exhibit gives the dimensioned footprints behind the numbers: Level 1 is an L shaped footprint, a 42 by 32 ft block plus a 22 by 28 ft block, totaling 1,960 sq ft. Level 2 is a single 42 by 32 ft rectangle that covers only the main block, smaller than the full Level 1 footprint. B1 repeats Level 1's footprint below grade.

SF3's dimensioned sketch footprints: Level 1 at 1,960 sq ft (a 42 by 32 ft block plus a 22 by 28 ft block, with the garage attached), Level 2 at 1,344 sq ft, B1 at the same footprint as Level 1, and the Accessory Dwelling Unit at 464 sq ft on its own 29 by 16 ft block.
GSE Sample Appraisal SF3, sketch exhibit.3
SF3's Area Calculations Summary: Floor 1, 1,960 sq ft (1,344 plus 616); Floor 2, 1,344 sq ft; Accessory Dwelling Unit, 464 sq ft; B1 finished below grade, 1,344 sq ft; B1 unfinished below grade, 616 sq ft; garage, 528 sq ft, Non-Living Area.
Same sketch, Area Calculations Summary.3

The attached garage, 22 by 24 ft, 528 sq ft, is labeled Non-Living Area in the sketch and excluded from every Area Breakdown field, which confirms the garage exclusion rule visually. The Cottage. SF3’s name for its accessory dwelling unit: a 464 sq ft, one-level structure with exterior access only. ADU, 464 sq ft, 29 by 16 ft, exterior access only, is never summed into the primary dwelling's GLA. It is a complete, separate Area Breakdown section; see our ADU reporting feature for financing and legal rentability mechanics.

Measured level by level

Watch the GLA build, level by level

  1. Level 11,960 sq ft
  2. Level 21,344 sq ft
  3. Level B1, finished1,344 sq ft
  4. Level B1, unfinished616 sq ft
  5. Garage, Non-Living Area528 sq ft
  6. Cottage ADU464 sq ft
Finished Above Grade0
Below grade (kept separate)0
Non-Living Area (excluded from totals)0
Cottage ADU (separate section)0
The tape draw's final totals
Finished Above Grade3,304 sq ft
Below grade, finished plus unfinished1,344 sq ft plus 616 sq ft
Garage, Non-Living Area528 sq ft, excluded from every total
Cottage ADU464 sq ft, separate section
The sketch, two waysPlan view or level stack

Plan and level stackThe dimensioned footprint, or the same numbers as a stacked massing, redrawn from the sketch's dimensions.

Level 1: 42 by 32 ftLevel 11,344 sq ftLevel 1 (wing): 22 by 28 ftWing616 sq ftAttached garage: 22 by 24 ft, 528 sq ft, Non-Living AreaGarage528 sq ftCottage ADU: 29 by 16 ftCottage464 sq ft28 ft
  • Above grade, living area
  • Below grade, Level B1
  • Garage, Non-Living Area
  • Cottage ADU, separate section

Dimensions and areas from the sketch's Area Calculations Summary.3 Generated from those numbers; no survey, plat or rendering from the source is reproduced.

Before trusting any single "total square footage" figure quoted for a multi unit or ADU property, confirm which Area Breakdown section it came from. SF3 alone has two complete, independently reported sections that must never be added together on the report.

06 / What movedNow in Dwelling Exterior

Noncontinuous and converted area leave Unit Interior

Noncontinuous Finished Area (8.046 to 8.048) is above grade finished space with no direct interior access, for example a family room reachable only through an attached garage. Dwelling Exterior reports it, separate from Unit Interior.1 Converted Area (8.012 to 8.013) rates a garage, patio or porch conversion Superior, Similar or Inferior against the rest of the living area, as a structured field. F-1's example reports a 1985 ranch with a converted garage rated Similar and a converted porch rated Inferior, as two separate rows.1

Noncontinuous Finished Area

8.046 Noncontinuous Finished Area Exists
Yes | No
8.047 Finished Total Area
Sq. ft.; multiple noncontinuous areas combine into one total
8.048 Room Summary
Count by room type, combined across all noncontinuous areas

Converted Area

8.012 Converted Area Exists
Yes | No; excludes below-grade finished area, reported in Unit Interior
8.013 Converted Area and Similarity to Rest of Living Area
Garage | Patio | Porch | Other, each rated Superior | Similar | Inferior
An unfinished attached garage interior, concrete floor and bare drywall, tools on a pegboard.
Before: an unfinished garage.
The same space converted into a finished living room with flooring, a rug and furniture.
After: converted to living space, rated against the rest of the home. AI-generated illustration pair.

A portfolio screen can now query "files where 8.012 is Yes or 8.046 to 8.048 are populated," instead of parsing commentary for converted space. RTL and DSCR renovation exit underwriting can use that screen now.

07 / The collateral risk lensWhat a rules engine can check today

What a rules engine can check in Section 7, 8 and 10 today

Fannie Mae and Freddie Mac already name, as a published error pattern, cases where the subject's nonstandard or unfinished area does not appear in the sales grid. Any AMC or QC vendor can encode that rule today.6 The subject's measurements are ANSI classified; comp data from MLS or an assessor is not.

Identical $425,000 sale, two classification callsAppendix 3's worked example: the same below grade area, reported two ways.

3,600 sq ft gross building finished area

$118 per sq ft

  1. Unit Interior 10.008, Unfinished Below Grade
  2. Level and Room Detail 10.031/10.032
  3. Sales Grid Unit(s) 22.07.13
  4. Dwelling(s) 22.05.04
  5. GRM Comp Grid 24.003

Source: Appendix F-1 v1.4, pp. 358 to 364.1 Two 1,607 sq ft units, 386 sq ft common stairwell, 1,800 sq ft below grade, $425,000 sale.

Gross Building Finished Area swings from 3,600 sq ft to 5,400 sq ft depending on whether the same below grade space is classified finished or unfinished. That reclassification moves price per square foot from $118 to $79, a swing of about 49 percent on an identical sale.

Checkable today versus needs human judgmentPoint at a zone for its field IDs and the rule that applies.

Checkable today

  • Vertical consistency, subject to grid10.00410.00510.00710.00822.07.0922.07.1022.07.1222.07.13
  • Levels in Unit row-count match10.01710.029 to 10.033
  • Converted and noncontinuous area present8.0128.0138.046 to 8.048

Needs human judgment

  • Which ANSI declaration applies7.0017.003
  • Whether a comp’s size is ANSI-equivalent10.009
Vertical consistency, subject to grid (checkable today)
10.004, 10.005, 10.007, 10.008, 22.07.09, 22.07.10, 22.07.12, 22.07.13: A field read and a cross reference; no judgment needed.
Levels in Unit row-count match (checkable today)
10.017, 10.029 to 10.033: A row count against a typed number.
Converted and noncontinuous area present (checkable today)
8.012, 8.013, 8.046 to 8.048: A field presence check, usable as a portfolio screen.
Which ANSI declaration applies (needs judgment)
7.001, 7.003: 7.003 is free text; no enumeration names the declaration type.
Whether a comp’s size is ANSI-equivalent (needs judgment)
10.009: MLS and assessor comp data have no measurement-standard field.
# Field IDs: Appendix F-1 v1.4. Thresholds and routing are the lender's choice.

# 1. Vertical consistency (Lessons Learned p. 9)
IF subject[10.004] > 0 OR subject[10.005] > 0 OR subject[10.007] > 0 OR subject[10.008] > 0:
    FOR comp IN grid[22.07.09, 22.07.10, 22.07.12, 22.07.13]:
        REQUIRE comp reports a consistent nonstandard or unfinished split
    ELSE FLAG "subject reports nonstandard or unfinished area not reflected in the grid"

# 2. Levels in Unit reconciliation (Lessons Learned p. 10)
computed_levels = COUNT(rows IN 10.029 to 10.033)
IF 10.017 != computed_levels:
    FLAG "Levels in Unit does not match row count"
# Appendix H-1's compliance rules (v1.5) check that each field is present. They do not check
# this specific cross consistency. A one-line, no-model check to run at intake.

# 3. Converted or noncontinuous area, an early rehab signal
IF 8.012 == Yes OR (8.046 to 8.048 populated):
    SURFACE on a "recently altered living area" portfolio screen
    CROSS REFERENCE 8.013's rating and the 8.047 total against permit records before closing

# 4. ANSI declaration structural gap
IF 7.001 == ANSI AND 7.003 contains no parseable declaration token:
    FLAG "ANSI declaration present only as free text"
    REQUIRE manual or NLP review before the file can be queried in aggregate

# 5. Subject vs. comp measurement mismatch (Appendix 3 worked example)
IF subject[10.009] includes "Physical Measurement" or "Three-Dimensional Scan"
   AND comp's reported GLA source is MLS or Assessor Record only:
    FLAG "subject is ANSI measured, comp is not independently verified"
    TREAT the $79 vs. $118 per sq ft swing as the realistic scale of classification risk
Field IDs from Appendix F-1 v1.4.1 Rule 1 restates Lessons Learned p. 9;6 thresholds and routing are a lender's choice.
08 / Scan tools and their limitsWhat LiDAR and floor plan apps do, and where they stop

What LiDAR and floor plan apps do, and where they stop

CubiCasa, inside Clear Capital's ClearInsight; OpalAi ScanTo3D; a la mode TOTAL for Mobile, which still needed manual square footage entry as of July 2026; and Matterport Cortex, covered below. None of the tools reviewed auto populates any of the six 3.6 Area Breakdown fields or classifies nonstandard area; each stops at producing a floor plan or a GLA number, leaving classification to the human appraiser.

  • CubiCasaSmartphone walkthrough to floor plan and digital GLA in about five minutes. Vendor source.
  • OpalAi ScanTo3DLiDAR scan to 2D or 3D floor plan with GLA and room labels. No published third-party error rates.
  • a la mode TOTAL for MobileLiDAR exterior scan to sketch; still needs manual square footage entry as of a July 2026 vendor blog.
  • Matterport CortexAI room and floor dimensions from digital twins. A 2022 industry-forum report states Matterport's team confirmed its output was not ANSI Z765-2021 compliant at that time.
Average appraiser-to-appraiser GLA variance0%, vendor source
Area RMSE, iPhone LiDAR vs. a total station0sq m, independent academic source

Sources: Clear Capital, Oct. 4, 2023;9 Saba and Saleh, Journal of Engineering Research, 2024.10 Separated by source type so neither is mistaken for the other's level of rigor.

A plausible near future, clearly speculative: a slope ceiling classifier applying the rule from Chapter 03 to a LiDAR height map, with the appraiser still making the calls a sensor cannot. Treat any vendor claim of "ANSI compliant" scan to sketch output as a claim about the floor plan and GLA number only. A classification claim would need the vendor to document how its scan handles the 50 percent rule, and none we reviewed do.

09 / ClosingA pre submission checklist

A pre submission checklist built from the GSEs' error list

Each item below is a check a rules engine or AMC QC process can run today, with no AI required. One open item remains: the undefined "AMS" measurement standard (7.001), noted here as something to watch.

Pre submission checklist

0 of 6 checked

Saved in this browser only.

Research checked November 2, 2026 against the GSE documents listed below, including the SF3 sample scenario (PDF, MISMO XML and sketch exhibit). The house and its interiors are fictional and were generated with Higgsfield; the form pages and SF3 sections are screenshots of GSE publications. General information, not legal, lending or appraisal advice.

Sources

13 documents
  1. Fannie Mae and Freddie Mac, Appendix F-1: URAR Reference Guide, v1.4, Sketch, Unit Interior and Dwelling Exterior sectionsMarch 10, 2026
  2. Fannie Mae and Freddie Mac, Appendix C-1: URAR layout, v1.3Current package
  3. Fannie Mae and Freddie Mac, GSE Sample Appraisal SF3, UAD 3.6 v1.4 (PDF, MISMO XML and sketch exhibit)Current package
  4. Fannie Mae and Freddie Mac, UAD Specification Appendix C: Form 1004/70 with numbered fieldsForm dated March 2005
  5. Fannie Mae and Freddie Mac, UAD ANSI Reporting Requirements job aid, Examples 1 to 9June 23, 2026
  6. Fannie Mae and Freddie Mac, UAD 3.6 Job Aid: Guidance for Appraisers through Lessons Learned, v1.0June 23, 2026
  7. Fannie Mae, UAD 3.6 Selling Guide Policy Supplement, SB4-1.3-05Sept. 2, 2026
  8. Fannie Mae, Selling Guide Announcement SEL-2025-04: terminology and ANSI/GXX001 retirement, effective Sept. 8, 2025June 4, 2025
  9. Clear Capital, "How to calculate gross living area digitally"Oct. 4, 2023
  10. Saba, R. and Saleh, M., "Evaluating LiDAR Technology in iPhone Mobiles for 2D Mapping Applications," Journal of Engineering Research2024
  11. Fannie Mae and Freddie Mac, Appendix H-1: UAD Compliance Rules for the URAR, v1.5Aug. 13, 2026
  12. Appraisal Institute, "Fannie Mae Adopts ANSI Standard for Square Footage Measurements"April 2022
  13. Pennsylvania Association of Realtors, "Freddie Mac Adopts ANSI Measuring Standards as of Nov. 2"Oct. 25, 2023

The Signal / Twice-monthly briefing

Get the next UAD 3.6 analysis in your inbox.

One sourced briefing twice a month on valuation policy, collateral risk and property technology.

Unsubscribe in one click. We don't sell your email or share it with sponsors. Privacy Policy

Found this useful? Share it